PDF file Selector Guide To Sound-Rated Partitions(1)
Side—41 mm (1 5 / *) studs 24*o.c. in two rows spaced 52 mm (2*) apart—steel truss member—gypsum panel gussets or stl run braces spanning chase screw-att to studs—panels screw att—joints stag & fin— UL Des U436 Double Wall Drywall—12.7 mm (1 ⁄ *) SHEETROCK brand gypsum panels, FIRECODE 57 TL … Retrieve Here

photos of Gypsum Tl

Product Selection Guide And Architectural Assemblies
Test Reference: RAL TL 10-196 Partition Thickness: 6” (152 mm) Weight per Sq. Ft.: 8.5 (41 Kg/m2) 5/8” (15.9 mm) ToughRock ® Fireguard ® gypsum board or 5/8” (15.9 mm) DensArmor … Read Document

Gypsum Tl images

PDF file Gypsum Board Partitions – Party Walls
2008 ~ National Gypsum Company Party Walls 2 Hour FIRE Design # WHI 651-0508 GA File # N/A STC – 50 Sound Test # NGC – 2826 Two Layers 1" (25.4 mm) x 24" Fire Sound test with 3-1/2" mineral wool or fiberglass insulation in stud cavity both sides = STC 61 (RAL-TL 05-199). … Retrieve Here

pictures of Gypsum Tl

PDF file Controlling Sound To Make Buildings More Functional …
12USGAcoustical Assemblies ASTM E90 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions wall (bearing or non-loadbearing) of wood or steel studs each side min 3/4* from liner panels •1/2* S HEETROCK Brand Gypsum Panels 11 1 ⁄ 2 " 46 RAL-TL-88-353 54 RAL-TL … Access Full Source

photos of Gypsum Tl

PDF file Gypsum Fire Wall
Typical Fire Wall Assembly S HEETROCK gypsum panels (as required) 50 x 100 mm (2 x 4) stud framing 25.4 mm (1) S HEETROCK Gypsum Liner Panels min. 19mm (3/4 wood or steel studs each side min 19mm (3/4) from liner panels • 12.7 mm (1/2)S HEETROCK Gypsum Panels 292 mm (11 1 ⁄ ") 89 mm (3 1 ⁄ ") 46 RAL-TL-88-353 54 … Access Full Source

Gypsum Tl images

PDF file Controlling Sound Transmission Through Concrete Block Walls
Estimating STC for Concrete Block Walls with Gypsum Board Added Normal-weight, non-porous block Data from an extensive series of measurements on normal-weight block walls were used to develop an empirical method for predicting STC for block walls with gypsum 4 Figure 3. Sound Transmission Loss (STC) for … Access Full Source

Gypsum Tl

PDF file The TL (Tectum & Lightweight) Non-Penetrating Fastener System …
LOAD CAPACITIES FOR TL FASTENER Substrate Material Pre-Drill Embedment Tension Load Tectum ® Deck-1 -1/2" 280 lbs. Tectum ® Deck-2" 440 lbs. Tectum ® Deck-2 -1/2" 595 lbs. 3" Insulrock 5/16" 2 -1/2" 365 lbs. Poured Gypsum 3/8" 2" 540 lbs. TL (Tectum & Lightweight) Fastener System FASTENER INSTALLATION INSTRUCTIONS AND … Retrieve Document

About Home Repair – Maintaining And Repairing Your House
Learn to easily repair and maintain your house and home. Get the HOW-TO home repair information you need with helpful tutorials, tool reviews, articles, hints and more from About Guide to Home Repair – architect and builder, Robert Formisano, AIA. … Read Article

YouTube HYDRA BOILER 514 602 8151 001 – YouTube
5:20 Add to Paper Machine & Stock Preparation Equipment – Gypsum Board Backing Paper by globalequipment100 2,271 views 0:31 Add to termotanque señorial instalado para salas de trabajo Argentina www.plomeriagomezhoy.es.tl by plomerohoy 12,919 views … View Video

pictures of Gypsum Tl

PDF file TF885 Sound Attenuation
O.c.—RC-1 chan or equivalent one side spaced 24 9 o.c. screw-att to studs—gypsum panels screw-att to studs & RC-1 channels—joints stag and fin— perimeter caulked— UL Des U419 or U451 rating also applies with I MPERIAL Brand gypsum base, F IRECODE C core, and veneer finish surface— RAL-TL-83-216 50 … Retrieve Doc

Gypsum Tl images

PDF file Gypsum Board Partitions – Steel Framing
2008 ~ National Gypsum Company Steel Stud Partitions 1 Hour FIRE Design # UL U420 GA File # WP 5015 STC – 52 Sound Test # TL-76-155 Chase wall, 5/8" (15.9 mm) Fire-Shield Gypsum Board applied vertically to a double row of 1-5/8" steel studs 24" o.c. and 6-1/4" apart with 1" type S screws 8" o.c … Content Retrieval

photos of Gypsum Tl

SITE BOOK – DriLyner
DriLyner www.british-gypsum.com Construction tips ● Estimated construction times ready for finishing, are as follows: – DriLyner BASIC 7m 2, DriLyner TL 6m 2, DriLyner MF 5m 2, DriLyner RF 11m 2, DriLyner SI 5m 2 per man hour ● To determine lining dimensions at reveals & soffits, allow for … Retrieve Document

Wikipedia Classification Of Minerals – Non Silicates – Wikipedia, The …
Bassanite 2CaSO 4 •H 2 O, Gypsum CaSO 4 •2H 2 O, Sanderite MgSO 4 •2H 2 O, Bonattite CuSO 4 •3H 2 O, Retgersite NiSO 4 •6H 2 O, Meridianiite MgSO 4 •11H 2 O Ag(Fe 3+) 3 (SO 4) 2 (OH) 6, Beaverite-Cu Pb(Fe 3+,Cu) 3 (SO 4) 2 (OH) 6 (Fe 3+:Cu ≈ 2:1), Beaverite-Zn Pb((Fe 3+) 2 Zn)(SO 4) 2 (OH) 6, Dorallcharite (Tl,K)(Fe 3+) 3 (SO 4) 2 … Read Article

Gypsum Tl pictures

Guide To Part L And Section 6
16 15 Gyproc Dri-Wall Adhesive Gyproc Dri-Wall Adhesive is a general purpose gypsum-based adhesive used in the British Gypsum DriLyner BASIC, SI, TL and MF systems on high, medium or low suction backgrounds. … Fetch Document

Gypsum Tl photos

PDF file Area Separation Wall
Typical Area Separation Wall Assembly 4 USG Area Separation Wall Systems Overview S heetrock ® brand gypsum panels (as required) 2 x 4 stud framing 1 S Protected wall (bearing or non-load-bearing) of wood or steel studs each side min 3/4 from liner panels • 1/2 S heetrock gypsum panels 46 RAL-TL … Retrieve Document

Gypsum Tl photos

PDF file Drywall/Wood Framed Systems
Fire-rated Construction Acoustical Performance Partition Applications Fire Detail & Physical Data Description & Test No. STC Description System Rating & Test No. Reference 2 hr. est. Stag Wd Stud—2 layers 15.9 mm (5/8*) S HEETROCK brand 47 TL-69-211 J gypsum panels, F IRECODE C core—2 x 4 400 mm (16*) o.c. on 2 x … Retrieve Doc

Gypsum Tl

PDF file Issue Date: 21st August 2006
Www.british-gypsum.com D r i L y n e r 4 DriLyner TL system – additional detailing Skirting fixing Ceiling to roof junction Junction with GypWall RAPID Partition at right angles to wall lining – standard detail. … Return Doc