Fire Safety Information
Laboratory setting or certifying or labeling of 5/8" type X wallboard as acceptable for use in one-hour fire rated assemblies type X gypsum wallboard, the Gypsum Association requires that all member companies relying on the generic assemblies/systems contained in the Gypsum Association's Fire … Fetch Content
SECTION 09265 – GYPSUM BOARD SHAFT-WALL ASSEMBLIES
GYPSUM BOARD SHAFT-WALL ASSEMBLIES, GENERAL; Provide materials and components complying with requirements of fire-resistance-rated assemblies indicated. … Retrieve Doc
Underwriters Laboratories – Wikipedia, The Free Encyclopedia
UL develops standards and test procedures for products, materials, components, assemblies, tools and equipment, chiefly dealing with product safety. UL published its first standard, “Tin Clad Fire Doors,” in 1903. The following year, the UL Mark made its debut with the labeling of a fire … Read Article
Assemblies
55 USG Fire-resistant Assemblies Exterior Walls Steel Framed F 2 Hour Fire–Rated Construction Non-Loadbearing Reference Construction Detail Description Test Number Comments ARL Index • 1" Sheetrock gypsum liner panels or U of C 4-2-75 Rating also applies with imperial SA700 F … Retrieve Full Source
NCMA Fires At Gypsum Wall Assemblies
Commonly used to evaluate gypsum wall assemblies, the results may have been different– even possibly demonstrating compliance with ASTM E 119 for a 2 hour rated assembly. The results of this series of fire endurance testing of gypsum panels, which was co-funded by the International … Fetch Here
Fire–Rated Assemblies
Fire–Rated Assemblies UL LISTED e 2 XP SH EAT HINGEXTERIOR PARTITIONS-STE ELFR AMIN G Fire RatingUL Design No. Description 1hr. U425 Load Bearing 1hr. U465 2hr. … Fetch Doc
UL G553 UL G564 Perpendicular View Parallel View – 2-Hour …
2-Hour Fire Rated Floor/Ceiling Assemblies Phone: 866-681-3405 Website: www.worthingtonibs.com SHEETROCK F/C “C” gypsum sheathing Ceiling: • Resilient channels @ 12” O.C. with 5/8” … View This Document
CertaPro Comm Catalog.1.9.03
Rating: 2 hour non-bearing (U 419) Rating: 2 hour non-bearing (U 419) Rating: 2 hour non-bearing (U 419) Rating: 2 hour non-bearing (U 419) Rating: 2 hour non-bearing (U 419) Double layer 1 / 2" Type X gypsum board 2 1 / 2" steel studs on 24" centers 2 1 / 2" Certainteed fiber glass insulation … Get Doc
YouTube – Broadcast Yourself.
And now you cite the passage where NIST says THIS, we all want read where NIST says "the fuel did not play a major role as combustive agent and did not help to combust low flammable material and did not such thing as spreading fire throughout the fire". … View Video
I-Stud For Fire Rated Cavity Shaftwall/Stairwell Assemblies
And U-Track components for Area Separation Wall Assemblies shall be consistent with methods and provisions described under above certifications; by test reports or fire–rated assemblies, by code evaluation reports and as indicated below. The recommendations below are referenced from National Gypsum's … Access This Document
SECTION 09260 – GYPSUM BOARD ASSEMBLIES
Clark Senior Center July 14, 2009 Page 1 SECTION 09260 – GYPSUM BOARD ASSEMBLIES PART 1 -GENERAL 1.1 SECTION REQUIREMENTS A. Submittals: Product Data. B. Fire-Resistance-Rated Assemblies: Provide materials and construction identical to those tested in assemblies per ASTM E 119 by an independent … Access Content
Truss Technology IN BUILDING
Sources of Information Fire rated assemblies are listed in the Fire Resistance Design Manual , published by the Gypsum Association (GA); the Fire Resistance Directory , published by Underwriters Laboratories, Inc. (UL); the Directory of Listed Building Products , published by Intertek Testing … Read Full Source
Gypsum Board Performance In fire rated Floor assemblies
Gypsum Board Performance in Fire Rated Floor Assemblies By M.A. Sultan This article presents some results from research performed by NRC-IRC on the fire performance of gypsum board, particularly the influence of several variables on the fall-off time. … Retrieve Full Source
Fire Rated Wall Assemblies
Fire Rated Wall Assemblies Based on the 2003 International Building Code Wall Type (code sec.) Ratings (hour) Doors (hour) Tbl 715.3 Windows 1 (hour) Tbl 715.4 Fire Dampers Tbl 716.3.1 Smoke Dampers Typical wall use Smoke Resisting 302.1.1.1 0 0, Self or auto closing, no air transfer grill NR NR NR Non rated incidental use … View Document
Fire–Rated Wood-Frame Wall And Floor/Ceiling Assemblies
2 FIRE–RATED WOOD-FRAME WALL AND FLOOR/CEILING ASSEMBLIES Table 1 One-Hour Fire–Rated Loadbearing Wood-Frame Wall Assemblies Assemblies Rated From Both Sides Studs Insulation Sheathing on Both Sides Fasteners Details 2×4 @ 16" o.c. 3½" mineral wool batts 5/8" Type X Gypsum Wallboard ( H ) 2¼ … Document Retrieval
Horizontal Shaftwall Duct And Ceiling Assemblies
137 cavity shaftwall systems 09 21 16.23 09 21 16.23/ngc duct j track gypsum board 1/2" fire-shield c power driven fasteners 24" o.c. power driven fasteners 24" o.c. 1/2 scale: 2" = 1'-0" flexible sealant horizontal shaftwall duct and ceiling assemblies description maximum horizontal spans for i-stud assemblies … Read Full Source